trustme.bro/r/…
✓ checked
trust me, bro:
here is the receipt.
the claim
Independent component analysis removes ocular artifacts from EEG signals.
the verdict
SUPPORTED
the evidence backs this
refutedsupported
the weight of evidence
8 sources for · 0 against

Multiple peer-reviewed studies establish that independent component analysis is a widely used and effective technique for identifying and removing ocular and other artifacts from electroencephalogram (EEG) recordings.

Evidence for · 8
2019 · cited by 0
Objective: The activity of the brain can be recorded by means of an electroencephalogram (EEG). An EEG is a multichannel signal related to brain activity. However, EEG presents a wide variety of undesired artefacts. Removal of these artefacts is often done using blind source separation methods (BSS) and mainly those based on Independent Component Analysis (ICA). ICA-based methods are well-accepted in the literature for filtering artefacts and have proved to be satisfactory in most scenarios of interest. Our goal is to develop a generic and unsupervised ICA-based algorithm for EEG artefacts removal. Approach: The proposed algorithm makes use of a new unsupervised artefact detection, ICA and a statistical criterion to automatically select the artefact related independent components (ICs) requiring no human intervention. The algorithm is evaluated using both simulated and real EEG data with artefacts (SEEG and AEEG). A comparison between the proposed unsupervised selection of ICs related to the artefact and other supervised selection is also presented. Main results: A new unsupervised ICA-based algorithm to filter artefacts, where ICs related to each artefact are automatically selected. It can be used in online applications, it preserves most of the original information among the artefacts and removes different types of artefacts. Significance: ICA-based methods for filtering artefacts prevail in the literature. The work in this article is important insofar as it addresses the p
See more details
The analysis

rails:sufficiency:supported:for=6+2p:against=0+0p | v55:sufficiency

More for · 7
2016 · cited by 0
Contamination of eye movement and blink artifacts in Electroencephalogram (EEG) recording makes the analysis of EEG data more difficult and could result in mislead findings. Efficient removal of these artifacts from EEG data is an essential step in improving classification accuracy to develop the brain-computer interface (BCI). In this paper, we proposed an automatic framework based on independent component analysis (ICA) and system identification to identify and remove ocular artifacts from EEG data by using hybrid EEG and eye tracker system. The performance of the proposed algorithm is illustrated using experimental and standard EEG datasets. The proposed algorithm not only removes the ocular artifacts from artifactual zone but also preserves the neuronal activity related EEG signals in non-artifactual zone. The comparison with the two state-of-the-art techniques namely ADJUST based ICA and REGICA reveals the significant improved performance of the proposed algorithm for removing eye movement and blink artifacts from EEG data. Additionally, results demonstrate that the proposed algorithm can achieve lower relative error and higher mutual information values between corrected EEG and artifact-free EEG data.
2006 · cited by 0
Simultaneous recording of electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) has been studied to identify areas related to EEG events. EEG data recorded in the magnetic resonance (MR) scanner with MR imaging is suffered from two specific artifacts, imaging artifact, and ballistocardiogram (BCG). In this paper, we focus on BCG. In preceding studies, average subtraction was often used for this purpose. However, average subtraction requires an assumption that BCG waveforms are precisely periodic, which seems unrealistic because BCG is a biomedical artifact. We propose the application of independent component analysis (ICA) with a postprocessing of high-pass filtering for the removal of BCG. With this approach, it is not necessary to assume that the BCG waveform is periodic. Empirically, we show that our proposed method removes BCG artifacts as well as does the average subtraction method. Power spectral density analysis of the two approaches shows that, with ICA, distortion of recovered EEG data is also as small as that associated with the average subtraction approach. We also propose a hypothesis for how head movement causes BCGs and show why ICA can remove BCG artifacts arising from this source.
2015 · cited by 0
Presence of artifacts in electroencephalographs (EEG) is major hurdles for the precise analysis of spectral behavior. For suppression of ocular artifact in EEG this paper proposes a component based Independent Component Analysis (ICA) model. It involves the generating a set of individual components of given signal followed by rejection of unwanted artifacts. Further this paper presents a novel method with combination of ICA, information sharing and double density wavelet transform to reject the artifacts from the signal. The Independent Component Analysis (ICA) here is used to segment artifact peaks in the signal. Then the Discrete Wavelet Transform is applied for multi-level transfer of signal data until the reception of significant result. The Wavelet ICA suppression not only removes artifacts but also preserves the spectral and coherence properties of brain signals.
2017 · cited by 0
A novel robust approach (OD-ICA), to remove OAs automatically.There is no need for an EOG reference signal.OD-ICA is successful in preserving the meaningful EEG signals.In OD-ICA, user intervention is not needed. ElectroEncephaloGram (EEG) gives information about the electrical characteristics of the brain. EEG can be used for various applications, such as diagnosis of diseases, neuroscience and Brain Computer Interface (BCI). Several artefacts sources can disturb the brain signals in EEG measurements. The signals caused by eye movements are the most important sources of artefacts that must be removed in order to obtain a clean EEG signal. During the removal of Ocular Artefacts (OAs), the preserve of the original EEG signal is one of the most important points to be taken into account. An ElectroOculoGram (EOG) reference signal is needed in order to remove OAs in some methods. However, long-term EOG measurements can disturb a subject. In this paper, a novel robust method is proposed in order to remove OAs automatically from EEG without EOG reference signal by combining Outlier Detection and Independent Component Analysis (OD-ICA). The OD-ICA method searches OA patterns in all components instead of a single component. Moreover, OD-ICA removes only OA patterns and preserves meaningful EEG signal. In this method, user intervention is not needed. These advantages make the method robust. The OD-ICA is tested on two real datasets. Relative Error (RE), Correlation Coefficient (CorrCo
2006 · cited by 0
To devise an automated system to remove artifacts from ictal scalp EEG, using independent component analysis (ICA).A Bayesian classifier was used to determine the probability that 2s epochs of seizure segments decomposed by ICA represented EEG activity, as opposed to artifact. The classifier was trained using numerous statistical, spectral, and spatial features. The system's performance was then assessed using separate validation data.The classifier identified epochs representing EEG activity in the validation dataset with a sensitivity of 82.4% and a specificity of 83.3%. An ICA component was considered to represent EEG activity if the sum of the probabilities that its epochs represented EEG exceeded a threshold predetermined using the training data. Otherwise, the component represented artifact. Using this threshold on the validation set, the identification of EEG components was performed with a sensitivity of 87.6% and a specificity of 70.2%. Most misclassified components were a mixture of EEG and artifactual activity.The automated system successfully rejected a good proportion of artifactual components extracted by ICA, while preserving almost all EEG components. The misclassification rate was comparable to the variability observed in human classification.Current ICA methods of artifact removal require a tedious visual classification of the components. The proposed system automates this process and removes simultaneously multiple types of artifacts.
2001 · cited by 0
'Independent component analysis' is a technique of data transformation that finds independent sources of activity in recorded mixtures of sources. It can be used to recover fluctuations of membrane potential from individual neurons in multiple-detector optical recordings. There are some examples in which more than 100 neurons can be separated simultaneously. Independent component analysis automatically separates overlapping action potentials, recovers action potentials of different sizes from the same neuron, removes artifacts and finds the position of each neuron on the detector array. One limitation is that the number of sources--neurons and artifacts--must be equal to or less than the number of simultaneous recordings. Independent component analysis also has many other applications in neuroscience including, removal of artifacts from EEG data, identification of spatially independent brain regions in fMRI recordings and determination of population codes in multi-unit recordings.
2016 · cited by 0
Eye movements (saccade, blink and etc.) cause artefacts in Electroencephalogram recordings. The ocular artefact can distort the EEG signals. Removal of ocular artefact is important issue in EEG signal analysis. The main task of artefact removal algorithms is to obtain cleaned EEG without losing meaningful EEG signal. The main focus of this work is to remove ocular artefact automatically by using Independent Component Analysis and Chauvenet criterion. The method is tested on real dataset. Relative error and Correlation coefficient are used for the performance test. The performance of the proposed method was Relative error= 0.273±0.148, Correlation coefficients 0.943± 0.042 in the dataset. The results show that the porposed method effectively removes ocular artefacts in EEG.
This receipt carries no identity, shared or not. Sharing publishes your connection to it, not your data.
Check your own claim
Challenge the receipt
trust me, bro: win the argument, pass the class, survive peer review.
This receipt is an automated verdict against our published method · not an opinion about any author or publication.
Terms · Privacy · How verdicts work · Dispute this receipt