trustme.bro/r/…
✓ checked
trust me, bro:
here is the receipt.
the claim
Accumulated dust layers can conduct electricity under sufficient humidity and voltage
the verdict
SUPPORTED
the evidence backs this
refutedsupported
the weight of evidence
1 source for · 0 against
AS REPORTEDno primary record reached; this is what the reporting says

Reference material notes that thin accumulated dust layers and high-resistivity dust significantly affect current-voltage characteristics and sparking voltage.

Evidence for · 1
cited by 0
has been observed with dust layers as thin as 0.1 mm, but a dust layer just over one particle thick can reduce the sparking voltage by 50%. The most marked An electrostatic precipitator (ESP) is a filterless device that removes fine particles, such as dust and smoke, from a flowing gas using the force of an induced electrostatic charge minimally impeding the flow of gases through the unit. In contrast to wet scrubbers, which apply energy directly to the flowing fluid medium, an ESP applies energy only to the particulate matter being collected and the An… Larger collection-surface areas and lower gas-flow rates increase efficiency because of the increased time available for electrical activity to treat the dust particles. An increase in the dust-particle migration velocity to the collecting electrodes increases efficiency. The migration velocity can be increased… Adjusting the temperature; Increasing moisture content; Adding conditioning agents to the gas stream; Increasing the collection surface area; and Using hot-side precipitators (occasionally and with foreknowledge of sodium depletion). Thin dust layers and high-resistivity dust especially favor the formation of back corona craters. Severe back corona has been observed with dust layers as thin as 0.1 mm, but a dust layer just over one particle thick can reduce the sparking voltage by 50%. The most marked effects of back corona on the current-voltage characteristics are: Reduc… Carbon can act, at first, like a high resistivity dust in the precipitator. Higher voltages can be required in order for corona generation to begin. These higher voltages can be problematic for the TR-Set controls. The problem lies in onset of corona causing large amounts of current to surge through the (low resistivity) dust layer. The controls sense this surge as a spark. As precipitators are operated in spark-limiting mode, power is terminated and the corona generation cycle re-initiates. Thus, lower power (current) readings are noted with relatively high voltage readings. The same thing is believed to occur in laboratory measurements. Parallel plate geometry is used in laboratory measurements without corona generation. A stainless steel cup holds the sample. Another stainless steel electrode weight sits on top of the sample (direct contact with the dust layer). As voltage is increased from small amounts (e.g. 20 V), no current is measured. Then, a threshold voltage level is reached. At this level, current surges through the sample... so much so that the voltage supply unit can trip off. After removal of the unburned combustibles during the above-mentioned annealing procedure, the descending temperature mode curve shows the typical inverted “V” shape one might expect.
See more details
The analysis

rails:sufficiency:supported:single_source:for=1+0p:against=0+0p | v55:sufficiency

Everything we examined (1)
This check searched the claim as stated. It did not run a separate search for evidence against it.
  1. Electrostatic precipitatorreferenceno side taken
This receipt carries no identity, shared or not. Sharing publishes your connection to it, not your data.
Check your own claim
Challenge the receipt
trust me, bro: win the argument, pass the class, survive peer review.
This receipt is an automated verdict against our published method · not an opinion about any author or publication.
Terms · Privacy · How verdicts work · Dispute this receipt